利用时空相干性的多帧反卷积增强超分辨率超声定位 Enhancing super-resolution ultrasound localisation through multi-frame deconvolution exploiting spatiotemporal coherence 预印本

⚠️ 本文为 预印本(arXiv 公开版本),尚未经过正式同行评审。作者自发公开,结论未经期刊审稿验证,阅读时请知悉。
发布时间:2024-07-08
👁️ 预览文献
💡 AI 中文简介
本研究针对超分辨率超声成像中微泡定位受噪声干扰的问题,提出多帧反卷积框架,利用时空相干性并设计空间和时间正则化(全变分和去噪正则化),开发了两种新方法。仿真实验表明,该方法在精度、召回率等指标上优于现有方法,定位精度提升高达39%,召回率提升12%。在活体大鼠脑数据集上生成的微血管图噪声更少、对比度和分辨率更高,血管结构更丰富。
领域医学超声成像/超分辨率显微成像
适合谁读需要一定专业背景(医学成像、信号处理领域的研究生或工程师)
核心贡献1. 提出多帧反卷积框架,利用时空相干性增强微泡定位;2. 设计基于全变分和去噪正则化的空间与时间正则项,并开发两种具体方法(MF-Decon+3DTV和MF-Decon+RED+TV),在仿真和活体数据上均优于现有方法。
关键数据仿真实验中,定位精度提升高达39%,召回率提升高达12%;在活体大鼠脑数据上生成的超分辨率微血管图噪声更少、对比度更高、分辨率更高且血管结构更丰富。
推荐理由如果你关注超声超分辨率成像或微泡定位,这篇工作通过多帧反卷积巧妙利用时空相干性,显著提升了定位性能,代码和数据公开,值得一读!
关键词["超分辨率超声", "微泡定位", "多帧反卷积", "时空相干性", "正则化", "超声定位显微镜"]

原文摘要

查看英文原文摘要

Super-resolution ultrasound imaging through microbubble (MB) localisation and tracking, also known as ultrasound localisation microscopy, allows non-invasive sub-diffraction resolution imaging of microvasculature in animals and humans. The number of MBs localised from the acquired contrast-enhanced ultrasound (CEUS) images and the localisation precision directly influence the quality of the resulting super-resolution microvasculature images. However, non-negligible noise present in the CEUS images can make localising MBs challenging. To enhance the MB localisation performance, we propose a Multi-Frame Deconvolution (MF-Decon) framework that can exploit the spatiotemporal coherence inherent in the CEUS data, with new spatial and temporal regularisers designed based on total variation (TV) and regularisation by denoising (RED). Based on the MF-Decon framework, we introduce two novel methods: MF-Decon with spatial and temporal TVs (MF-Decon+3DTV) and MF-Decon with spatial RED and temporal TV (MF-Decon+RED+TV). Results from in silico simulations indicate that our methods outperform two widely used methods using deconvolution or normalised cross-correlation across all evaluation metrics, including precision, recall, $F_1$ score, mean and standard localisation errors. In particular, our methods improve MB localisation precision by up to 39% and recall by up to 12%. Super-resolution microvasculature maps generated with our methods on a publicly available in vivo rat brain dataset show less noise, better contrast, higher resolution and more vessel structures.