基于残差U-Net的光学相干层析成像图像增强去噪 Enhanced Denoising of Optical Coherence Tomography Images Using Residual U-Net 预印本

⚠️ 本文为 预印本(arXiv 公开版本),尚未经过正式同行评审。作者自发公开,结论未经期刊审稿验证,阅读时请知悉。
发布时间:2024-07-18
👁️ 预览文献
💡 AI 中文简介
光学相干层析成像(OCT)在眼科诊断中很重要,但图像中的散斑噪声影响诊断准确性。本研究提出一种基于残差U-Net的增强去噪模型,能同时处理前节OCT和偏振敏感OCT图像。结果显示,偏振敏感OCT图像的峰值信噪比达到34.343±1.113,结构相似性为0.885±0.030;前节OCT图像的峰值信噪比为23.525±0.872 dB,结构相似性为0.407±0.044。该方法在去噪的同时保留了关键解剖特征,有助于提高临床诊断的精确性和效率。
领域医学图像处理/计算机视觉
适合谁读需要一定专业背景
核心贡献1. 提出基于残差U-Net的增强去噪模型,可同时适用于前节OCT和偏振敏感OCT两种模态;2. 在去噪的同时有效保留组织完整性和纹理细节,提升图像质量指标。
关键数据偏振敏感OCT:PSNR 34.343±1.113,SSIM 0.885±0.030;前节OCT:PSNR 23.525±0.872 dB,SSIM 0.407±0.044。
推荐理由如果你关注医学图像去噪,尤其是OCT图像,这篇论文用残差U-Net在两种模态上都取得了不错的效果,值得一读。
关键词["光学相干层析成像", "图像去噪", "残差U-Net", "散斑噪声", "医学图像处理"]

原文摘要

查看英文原文摘要

Optical Coherence Tomography (OCT) imaging is pivotal in diagnosing ophthalmic conditions by providing detailed cross-sectional images of the anterior and posterior segments of the eye. Nonetheless, speckle noise and other imaging artifacts inherent to OCT impede the accuracy of diagnosis significantly. In this study, we proposed an enhanced denoising model using a Residual U-Net architecture that effectively diminishes noise and improves image clarity across both Anterior Segment OCT (ASOCT) and polarization-sensitive OCT (PSOCT) images. Our approach demonstrated substantial improvements in image quality metrics: the Peak Signal Noise Ratio (PSNR) was 34.343 $\pm$ 1.113 for PSOCT images, and Structural Similarity Index Measure (SSIM) values were 0.885 $\pm$ 0.030, indicating enhanced preservation of tissue integrity and textural details. For ASOCT images, we observed the PSNR to be 23.525 $\pm$ 0.872 dB and SSIM 0.407 $\pm$ 0.044, reflecting significant enhancements in visual quality and structural accuracy. These metrics substantiate the models efficacy in not only reducing noise but also in maintaining crucial anatomical features, thereby enabling more precise and efficient clinical evaluations. The dual functionality across both ASOCT and PSOCT modalities underscores the versatility and potential for broad application in clinical settings, optimizing diagnostic processes and reducing the necessity for prolonged imaging sessions.