面向肺癌计算机断层扫描的肿瘤感知循环式患者间可变形图像配准 Tumor aware recurrent inter-patient deformable image registration of computed tomography scans with lung cancer 预印本

⚠️ 本文为 预印本(arXiv 公开版本),尚未经过正式同行评审。作者自发公开,结论未经期刊审稿验证,阅读时请知悉。
发布时间:2024-09-18
👁️ 预览文献
💡 AI 中文简介
本研究针对肺癌放疗中患者间可变形图像配准(DIR)易受肿瘤干扰的问题,提出了一种肿瘤感知循环配准(TRACER)深度学习方法。该方法利用3D卷积长短期记忆网络逐步计算形变场,并引入肿瘤分割信息与双向肿瘤刚性损失,实现无监督训练。在三个数据集(共1115对CT图像)上评估,TRACER能准确对齐正常组织,同时最大程度保留肿瘤形态,肿瘤体积差异最小仅0.13%,放疗剂量差异低至0.01 Gy,为群体水平放疗结果建模提供了可靠工具。
领域医学图像处理/放疗
适合谁读需要一定专业背景(医学图像分析或放疗领域研究者)
核心贡献1. 提出肿瘤感知循环配准(TRACER)网络,通过3D-CLSTM逐步计算形变场,并引入肿瘤分割作为输入条件,有效避免肿瘤导致的非真实形变。2. 设计双向肿瘤刚性损失、图像相似性损失和形变平滑损失,实现无监督训练,在多个数据集上肿瘤保留和剂量计算精度均优于现有方法。
关键数据在数据集I(308对)、II(765对)、III(42例)上,肿瘤体积差异分别为0.24%、0.40%、0.13%;CT强度均方误差分别为0.005、0.005、0.004;放疗计划肿瘤剂量差异在使用女性和男性参考时分别为0.01 Gy和0.013 Gy。
推荐理由如果你关注肺癌放疗中的图像配准精度,这项研究用深度学习巧妙解决了肿瘤干扰难题,数据扎实,值得一读。
关键词["可变形图像配准", "肺癌", "深度学习", "肿瘤感知", "放疗", "计算机断层扫描"]

原文摘要

查看英文原文摘要

Background: Voxel-based analysis (VBA) for population level radiotherapy (RT) outcomes modeling requires topology preserving inter-patient deformable image registration (DIR) that preserves tumors on moving images while avoiding unrealistic deformations due to tumors occurring on fixed images. Purpose: We developed a tumor-aware recurrent registration (TRACER) deep learning (DL) method and evaluated its suitability for VBA. Methods: TRACER consists of encoder layers implemented with stacked 3D convolutional long short term memory network (3D-CLSTM) followed by decoder and spatial transform layers to compute dense deformation vector field (DVF). Multiple CLSTM steps are used to compute a progressive sequence of deformations. Input conditioning was applied by including tumor segmentations with 3D image pairs as input channels. Bidirectional tumor rigidity, image similarity, and deformation smoothness losses were used to optimize the network in an unsupervised manner. TRACER and multiple DL methods were trained with 204 3D CT image pairs from patients with lung cancers (LC) and evaluated using (a) Dataset I (N = 308 pairs) with DL segmented LCs, (b) Dataset II (N = 765 pairs) with manually delineated LCs, and (c) Dataset III with 42 LC patients treated with RT. Results: TRACER accurately aligned normal tissues. It best preserved tumors, blackindicated by the smallest tumor volume difference of 0.24\%, 0.40\%, and 0.13 \% and mean square error in CT intensities of 0.005, 0.005, 0.004, computed between original and resampled moving image tumors, for Datasets I, II, and III, respectively. It resulted in the smallest planned RT tumor dose difference computed between original and resampled moving images of 0.01 Gy and 0.013 Gy when using a female and a male reference.