基于深度学习的腹部器官CT扫描自动分割与测量工作流 Deep Learning-Based Automated Workflow for Accurate Segmentation and Measurement of Abdominal Organs in CT Scans 预印本

⚠️ 本文为 预印本(arXiv 公开版本),尚未经过正式同行评审。作者自发公开,结论未经期刊审稿验证,阅读时请知悉。
发布时间:2025-03-13
👁️ 预览文献
💡 AI 中文简介
本研究开发了一套深度学习自动工作流,用于CT扫描中腹部器官(肾脏、肝脏、脾脏、前列腺)的分割与测量。方法上结合了nnU-Net和U-Net++进行器官分割,再用3D RCNN模型测量体积和尺寸。在CT数据集上训练评估后,所有器官的精确率和召回率均超过95%,测量误差很低,说明自动测量与真实值高度一致。该工作流能减少人工操作,提高诊断效率和一致性,有望在临床推广。
领域医学图像处理/计算机视觉
适合谁读需要一定专业背景(医学图像分析或深度学习基础)
核心贡献1. 提出结合nnU-Net、U-Net++和3D RCNN的自动工作流,实现腹部多器官分割与测量一体化;2. 在CT数据上验证了高精度(精确率/召回率>95%)和低测量误差,证明其临床可用性。
关键数据精确率和召回率均超过95%;平均平方误差(MSE)低,预测与真实值高度一致;对肾脏、肝脏、脾脏、前列腺分割和测量表现稳健。
推荐理由如果你关注医学影像的自动分析,这篇工作展示了如何用深度学习一站式搞定腹部器官的分割和测量,精度高且省时省力,值得一读。
关键词["深度学习", "CT扫描", "腹部器官分割", "自动测量", "nnU-Net", "3D RCNN"]

原文摘要

查看英文原文摘要

Background: Automated analysis of CT scans for abdominal organ measurement is crucial for improving diagnostic efficiency and reducing inter-observer variability. Manual segmentation and measurement of organs such as the kidneys, liver, spleen, and prostate are time-consuming and subject to inconsistency, underscoring the need for automated approaches. Purpose: The purpose of this study is to develop and validate an automated workflow for the segmentation and measurement of abdominal organs in CT scans using advanced deep learning models, in order to improve accuracy, reliability, and efficiency in clinical evaluations. Methods: The proposed workflow combines nnU-Net, U-Net++ for organ segmentation, followed by a 3D RCNN model for measuring organ volumes and dimensions. The models were trained and evaluated on CT datasets with metrics such as precision, recall, and Mean Squared Error (MSE) to assess performance. Segmentation quality was verified for its adaptability to variations in patient anatomy and scanner settings. Results: The developed workflow achieved high precision and recall values, exceeding 95 for all targeted organs. The Mean Squared Error (MSE) values were low, indicating a high level of consistency between predicted and ground truth measurements. The segmentation and measurement pipeline demonstrated robust performance, providing accurate delineation and quantification of the kidneys, liver, spleen, and prostate. Conclusion: The proposed approach offers an automated, efficient, and reliable solution for abdominal organ measurement in CT scans. By significantly reducing manual intervention, this workflow enhances measurement accuracy and consistency, with potential for widespread clinical implementation. Future work will focus on expanding the approach to other organs and addressing complex pathological cases.