基于深度图像先验的有限角度SPECT图像重建 Limited-angle SPECT image reconstruction using deep image prior 预印本

⚠️ 本文为 预印本(arXiv 公开版本),尚未经过正式同行评审。作者自发公开,结论未经期刊审稿验证,阅读时请知悉。
发布时间:2025-03-24
⬇️ 3 次下载
👁️ 预览文献
💡 AI 中文简介
针对SPECT成像在有限角度下因投影数据不全导致图像扭曲的问题,本研究提出一种端到端的深度图像先验(DIP)重建框架。该方法将前向投影模型和指示数据是否采集的二值掩模融入损失函数,从而恢复未采集角度的投影数据。在20个数值体模和临床患者数据上验证,结果显示该方法在PSNR和SSIM上优于传统反投影方法,并显著改善了几乎所有空间频率的响应,有效减轻了图像失真。
领域医学图像处理/SPECT图像重建
适合谁读需要一定专业背景(医学成像、深度学习)
核心贡献1. 提出端到端DIP框架,将前向投影模型与二值掩模融入损失函数,直接恢复未采集投影数据;2. 在有限角度条件下显著改善图像质量,频率域响应提升明显。
关键数据在20个数值体模和临床数据上,PSNR和SSIM优于现有反投影方法;几乎所有空间频率响应显著提升,包括未采集角度范围。
推荐理由如果你关注医学图像重建或有限角度问题,这篇工作用深度图像先验巧妙恢复了丢失的频率信息,效果显著,值得一读。
关键词["SPECT重建", "有限角度", "深度图像先验", "端到端学习", "二值掩模", "调制传递函数"]

原文摘要

查看英文原文摘要

In SPECT image reconstruction, limited-angle (LA) conditions lead to a loss of frequency components, which distort the reconstructed tomographic image along directions corresponding to the non-collected projection angle range. Although conventional iterative image reconstruction methods have been used to improve the reconstructed images in LA conditions, the image quality is still unsuitable for clinical use. We propose a LA SPECT image reconstruction method that uses an end-to-end deep image prior (DIP) framework to improve reconstructed image quality. The proposed LA SPECT image reconstruction is an end-to-end DIP framework which incorporates a forward projection model into the loss function to optimise the neural network. By also incorporating a binary mask that indicates whether each data point in the measured projection data has been collected, the proposed method restores the non-collected projection data and reconstructs a less distorted image. The proposed method was evaluated using 20 numerical phantoms and clinical patient data. In numerical simulations, the proposed method outperformed existing back-projection-based methods in terms of PSNR and SSIM. We analysed the reconstructed tomographic images in the frequency domain using an object-specific modulation transfer function, in simulations and on clinical patient data, to evaluate the response of the reconstruction method to different frequencies of the object. The proposed method significantly improved the response to almost all spatial frequencies, even in the non-collected projection angle range. The results demonstrate that the proposed method reconstructs a less distorted tomographic image. The proposed end-to-end DIP-based reconstruction method restores lost frequency components and mitigates image distortion under LA conditions by incorporating a binary mask into the loss function.