边缘端时间序列分析:用于可穿戴步态检测与最优传感器布置的微型可分离卷积神经网络 Time-Series at the Edge: Tiny Separable CNNs for Wearable Gait Detection and Optimal Sensor Placement 预印本

⚠️ 本文为 预印本(arXiv 公开版本),尚未经过正式同行评审。作者自发公开,结论未经期刊审稿验证,阅读时请知悉。
发布时间:2025-11-29
👁️ 预览文献
💡 AI 中文简介
本研究针对帕金森病患者的可穿戴步态检测,探索在资源受限的边缘设备上直接进行时间序列分析。作者用三轴加速度短窗口数据,比较了幅值阈值法和三种一维卷积神经网络(含文献基线与两种超轻量模型)。在BioStampRC21数据集上,采用2秒窗口、30Hz采样和留一受试者验证,残差可分离模型仅533个参数就达到PR-AUC 94.5%、F1 91.2%,与参数多约10倍的基线相当甚至更优。研究还发现胸部和大腿传感器最可靠,并证明这些模型可在STM32级单片机上亚10毫秒内运行,实现传感器端数据筛选。
领域边缘计算与可穿戴健康监测(时间序列分析、嵌入式机器学习)
适合谁读需要一定专业背景(了解深度学习、可穿戴传感与边缘计算基础)
核心贡献1. 提出两种超轻量可分离一维CNN,以约10倍更少参数达到或超越文献基线,实现精度-效率-泛化性的更优权衡;2. 系统评估传感器位置对步态检测的影响,发现胸部和大腿最可靠,并证明简单融合多部位并不优于最佳单点。
关键数据残差可分离模型(Model 2,533参数):PR-AUC=94.5%,F1=91.2%,MCC=89.4%;最小模型(Model 1,305参数):PR-AUC=94.0%,F1=91.0%,MCC=89.1%;基线(5,552参数):PR-AUC=93.7%,F1=90.5%,MCC=88.5%;阈值法召回89.0%但精确率仅76.5%;STM32级MCU上推理时间低于10毫秒。
推荐理由如果你关心如何在极低功耗的可穿戴设备上实现高精度步态检测,这篇论文用几百个参数就做到了,还告诉你传感器该戴在哪里,非常实用。
关键词["帕金森病", "步态检测", "边缘计算", "可分离卷积", "可穿戴传感器", "时间序列分析"]

原文摘要

查看英文原文摘要

We study on-device time-series analysis for gait detection in Parkinson's disease (PD) from short windows of triaxial acceleration, targeting resource-constrained wearables and edge nodes. We compare magnitude thresholding to three 1D CNNs for time-series analysis: a literature baseline (separable convolutions) and two ultra-light models - one purely separable and one with residual connections. Using the BioStampRC21 dataset, 2 s windows at 30 Hz, and subject-independent leave-one-subject-out (LOSO) validation on 16 PwPD with chest-worn IMUs, our residual separable model (Model 2, 533 params) attains PR-AUC = 94.5%, F1 = 91.2%, MCC = 89.4%, matching or surpassing the baseline (5,552 params; PR-AUC = 93.7%, F1 = 90.5%, MCC = 88.5%) with approximately 10x fewer parameters. The smallest model (Model 1, 305 params) reaches PR-AUC = 94.0%, F1 = 91.0%, MCC = 89.1%. Thresholding obtains high recall (89.0%) but low precision (76.5%), yielding many false positives and high inter-subject variance. Sensor-position analysis (train-on-all) shows chest and thighs are most reliable; forearms degrade precision/recall due to non-gait arm motion; naive fusion of all sites does not outperform the best single site. Both compact CNNs execute within tight memory/latency budgets on STM32-class MCUs (sub-10 ms on low-power boards), enabling on-sensor gating of transmission/storage. Overall, ultra-light separable CNNs provide a superior accuracy-efficiency-generalization trade-off to fixed thresholds for wearable PD gait detection and underscore the value of tailored time-series models for edge deployment.