基于多体积潜在一致性模型的有限角度CT重建 Limited-Angle CT Reconstruction Using Multi-Volume Latent Consistency Model 预印本

⚠️ 本文为 预印本(arXiv 公开版本),尚未经过正式同行评审。作者自发公开,结论未经期刊审稿验证,阅读时请知悉。
发布时间:2026-03-05
👁️ 预览文献
💡 AI 中文简介
本研究提出一种用于有限角度CT重建的多体积潜在扩散模型,通过引入一致性模型实现快速稳定推理,并利用多体积编码器从全局和中心区域获取不同尺度的潜在变量,以在不同视野条件下保留器官边界和内部结构。在60度有限角度下,MAE为10.12 HU,SSIM为0.9677;在30度极端有限角度下,MAE为16.69 HU,SSIM为0.9393。该方法对未知投影角度条件也表现出稳定性能,适用于临床多样成像场景。
领域医学图像重建
适合谁读需要一定专业背景
核心贡献["提出多体积潜在一致性模型,利用多尺度潜在表示引导有限角度CT重建,提升不同视野下的重建精度。", "引入一致性模型加速推理,并在60度和30度有限角度下实现高精度重建,且对未知角度条件具有鲁棒性。"]
关键数据60度有限角度:MAE 10.12 HU, SSIM 0.9677;30度有限角度:MAE 16.69 HU, SSIM 0.9393
推荐理由该研究为有限角度CT重建提供了新思路,通过多体积潜在一致性模型在极端角度下仍能保持高精度,值得医学影像领域研究者关注。
关键词["有限角度CT重建", "潜在扩散模型", "一致性模型", "多体积编码器", "图像合成"]

原文摘要

查看英文原文摘要

Limited-angle computed tomography (LACT) reconstruction is an inverse problem with severe ill-posedness arising from missing projection angles, and it is difficult to restore high-precision images without sufficient prior knowledge. In recent years, machine learning methods represented by diffusion models have demonstrated high image generation capabilities. However, accurate restoration of three-dimensional structures of organs and vessels and preservation of contrast remain challenges, and the impact of differences in diverse clinical imaging conditions such as field of view (FOV) and projection angle range on reconstruction accuracy has not been sufficiently investigated. In this study, we propose a multi-volume latent diffusion model that uses three-dimensional latent representations obtained from multiple effective fields of view as guidance for LACT reconstruction in clinical practical problems. The proposed method achieves fast and stable inference by introducing consistency models into latent space, and enables high-precision preservation of organ boundary information and internal structures under different FOV conditions through a Multi-volume encoder that acquires latent variables from different scales of the global region and central region. The evaluation experiments demonstrated that the proposed method achieved high-precision synthetic CT image generation compared to existing methods. Under the limited-angle condition of 60 degrees, MAE of 10.12 HU and SSIM of 0.9677 were achieved, and under the extreme limited-angle condition of 30 degrees, MAE of 16.69 HU and SSIM of 0.9393 were achieved. Furthermore, stable reconstruction performance was demonstrated even for unknown projection angle conditions not included during training, confirming the applicability to diverse imaging conditions in clinical practice.