探索基于面部视频的远程光电容积描记法用于新生儿疼痛检测 Exploring Remote Photoplethysmography for Neonatal Pain Detection from Facial Videos 预印本

⚠️ 本文为 预印本(arXiv 公开版本),尚未经过正式同行评审。作者自发公开,结论未经期刊审稿验证,阅读时请知悉。
发布时间:2026-04-28
👁️ 预览文献
💡 AI 中文简介
新生儿疼痛若未妥善处理,可能影响发育和体重增长。传统接触式监测不适合长期使用,且有感染风险。本研究提出用远程光电容积描记(rPPG)技术,从面部视频非接触地提取脉搏信号来检测疼痛。由于面部皮肤变形会影响信号质量,研究引入质量参数筛选受影响最小的区域,并用信噪比挑选噪声最小的信号。实验发现,蓝色通道的rPPG信号效果最好,且结合音频特征能进一步提升检测性能。
领域计算机视觉与医学人工智能(情感计算)
适合谁读需要一定专业背景(医学影像、信号处理、新生儿护理相关研究者)
核心贡献首次将rPPG技术应用于新生儿疼痛检测,并引入信号质量筛选机制;证明结合音频特征可提升检测性能。
关键数据蓝色通道rPPG信号优于其他通道;结合音频特征优于单一模态。
推荐理由想了解非接触式生理信号在医疗场景应用,这篇论文提供了新颖的思路和实验验证,值得一读。
关键词["新生儿疼痛检测", "远程光电容积描记", "非接触式疼痛检测", "情感计算", "面部视频分析"]

原文摘要

查看英文原文摘要

Unaddressed pain in neonates can lead to adverse effects, including delayed development and slower weight gain, emphasising the need for more objective and reliable pain assessment methods. Hence, automated methods using behavioural and physiological pain indicators have been developed to aid healthcare professionals in the Neonatal ICU. Traditional contact-based methods for physiological parameter estimation are unsuitable for long-term monitoring and increase the risk of spreading diseases like COVID-19. We introduce a novel approach using remote photoplethysmography (rPPG) to estimate pulse signals in a non-contact manner and employ them for neonatal pain detection. The temporal signals acquired from regions-of-interest (ROIs) affected by skin deformations may exhibit lower quality and provide erroneous rPPG signals. Therefore, we incorporated a quality parameter to select the temporal signals obtained from ROIs that are least affected by skin deformations. Further, we employed signal-to-noise ratio as a fitness parameter to extract the rPPG signal corresponding to the clip that is least affected by noise. Experimental findings demonstrate that the rPPG signals provide useful information for neonatal pain detection, and signals extracted from the blue colour channel outperform those extracted from other colour channels. We also show that combining rPPG and audio features provides better results than individual modalities.

📚 参考文献 (84 条)

查看全部 84 条
  1. [1] Brahnam, S., Nanni, L., McMurtrey, S., Lumini, A., Brattin, R., Slack, M., Bar- rier, T.: Neonatal pain detection in videos using the iCOPEvid dataset and an ensemble of descriptors extracted from Gaussian of Local Descriptors. Applied Computing and Informatics 19, 122–143 (2023)
  2. [2] Zamzmi, G., Kasturi, R., Goldgof, D., Zhi, R., Ashmeade, T., Sun, Y.: A review of automated pain assessment in infants: features, classification tasks, and databases. IEEE Reviews in Biomedical Engineering 11, 77–96 (2017)
  3. [3] Cheng, X., Zhu, H., Mei, L., Luo, F., Chen, X., Zhao, Y., Chen, S., Pan, Y.: Artificial intelligence based pain assessment technology in clinical application of real-world neonatal blood sampling. Diagnostics 12, 1831 (2022)
  4. [4] Zamzmi, G., Pai, C.-Y., Goldgof, D., Kasturi, R., Ashmeade, T., Sun, Y.: An approach for automated multimodal analysis of infants’ pain. In: International Conference on Pattern Recognition, pp. 4148–4153 (2016)
  5. [5] Page, G.G.: Are there long-term consequences of pain in newborn or very young infants? The Journal of Perinatal Education 13, 10–17 (2004)
  6. [6] Mathews, L.: Pain in children: neglected, unaddressed and mismanaged. Indian Journal of Palliative Care 17, 70 (2011)
  7. [7] Meyer, S., Bay, J.P., Poryo, M.: Staffing, skill mix, shortage, and survival in the NICU and PICU: pediatrics quo vadis? European Journal of Pediatrics, 1–2 (2023)
  8. [8] Ritu, J.T., Shakil, M.S.H., Hasan, M.N.I., Al Mamun, S., Kaiser, M.S., Mahmud, M.: Facial detection for neonatal infant pain using facial geometry features and LBP. In: International Conference on Trends in Computational and Cognitive Engineering, pp. 509–518 (2022)
  9. [9] Sun, M., Wang, H., Yao, W., Liu, J.: AuE-IPA: An AU engagement based infant pain assessment method. arXiv preprint arXiv:2212.04764 (2022)
  10. [10] Lu, G., Chen, H., Wei, J., Li, X., Zheng, X., Leng, H., Lou, Y., Yan, J.: Video-based neonatal pain expression recognition with cross-stream attention. Multimedia Tools and Applications, 1–24 (2023) 18
  11. [11] Salekin, M.S., Zamzmi, G., Paul, R., Goldgof, D., Kasturi, R., Ho, T., Sun, Y.: Harnessing the power of deep learning methods in healthcare: Neonatal pain assessment from crying sound. In: IEEE Healthcare Innovations and Point of Care Technologies, pp. 127–130 (2019)
  12. [12] Zamzmi, G., Pai, C.-Y., Goldgof, D., Kasturi, R., Sun, Y., Ashmeade, T.: Automated pain assessment in neonates. In: Image Analysis, pp. 350–361 (2017)
  13. [13] Jiang, M., Rosio, R., Salanter¨a, S., Rahmani, A.M., Liljeberg, P., Silva, D.S., Albuquerque, V.H.C., Wu, W.: Personalized and adaptive neural networks for pain detection from multi-modal physiological features. Expert Systems with Applications 235, 121082 (2024)
  14. [14] Birla, L., Puneet, G.: AND-rPPG: A novel denoising-rPPG network for improving remote heart rate estimation. Computers in Biology and Medicine 141, 105146 (2022)
  15. [15] Gupta, P., Bhowmick, B., Pal, A.: MOMBAT: Heart rate monitoring from face video using pulse modeling and Bayesian tracking. Computers in Biology and Medicine 121, 103813 (2020)
  16. [16] Gupta, A.K., Kumar, R., Birla, L., Gupta, P.: RADIANT: Better rPPG estima- tion using signal embeddings and Transformer. In: IEEE/CVF Winter Conference on Applications of Computer Vision, pp. 4976–4986 (2023)
  17. [17] Saikia, T., Birla, L., Gupta, A.K., Gupta, P.: HREADAI: Heart rate estimation from face mask videos by consolidating Eulerian and Lagrangian approaches. IEEE Transactions on Instrumentation and Measurement (2023)
  18. [18] Li, P., Benezeth, Y., Nakamura, K., Gomez, R., Li, C., Yang, F.: An improvement for video-based heart rate variability measurement. In: International Conference on Signal and Image Processing, pp. 435–439 (2019). IEEE
  19. [19] Alnaggar, M., Siam, A.I., Handosa, M., Medhat, T., Rashad, M.: Video-based real-time monitoring for heart rate and respiration rate. Expert Systems with Applications 225, 120135 (2023)
  20. [20] Agarwal, V., Saikia, T., Gupta, A.K., Gupta, P.: SHINE: Synergizing transform- ers with contrastive learning for thriving rPPG-based SpO2 estimation. Expert Systems with Applications, 129190 (2025)
  21. [21] Huang, B., Chen, W., Lin, C.-L., Juang, C.-F., Xing, Y., Wang, Y., Wang, J.: A neonatal dataset and benchmark for non-contact neonatal heart rate monitoring based on spatio-temporal neural networks. Engineering Applications of Artificial Intelligence 106, 104447 (2021)
  22. [22] Malafaya, D., Domingues, S., Oliveira, H.P.: Domain adaptation for heart rate 19
  23. extraction in the Neonatal Intensive Care Unit. In: IEEE International Conference on Bioinformatics and Biomedicine, pp. 1082–1086 (2020)
  24. [23] Brahnam, S., Chuang, C.-F., Shih, F.Y., Slack, M.R.: SVM classification of Neonatal facial images of pain. In: Fuzzy Logic and Applications, pp. 121–128 (2006)
  25. [24] Brahnam, S., Chuang, C., Shih, F.Y., Slack, M.R.: Machine recognition and rep- resentation of neonatal facial displays of acute pain. Artificial Intelligence in Medicine 36, 211–222 (2006)
  26. [25] Schiavenato, M., Byers, J.F., Scovanner, P., McMahon, J.M., Xia, Y., Lu, N., He, H.: Neonatal pain facial expression: Evaluating the primal face of pain. Pain 138, 460–471 (2008)
  27. [26] Grunau, R.V., Craig, K.D.: Pain expression in Neonates: facial action and cry. Pain 28, 395–410 (1987)
  28. [27] Celona, L., Manoni, L.: Neonatal facial pain assessment combining hand-crafted and deep features. In: New Trends in Image Analysis and Processing, pp. 197–204 (2017)
  29. [28] Yan, J., Lu, G., Li, X., Zheng, W., Huang, C., Cui, Z., Zong, Y., Chen, M., Hao, Q., Liu, Y., et al.: FENP: a database of neonatal facial expression for pain analysis. IEEE Transactions on Affective Computing (2020)
  30. [29] Salekin, M.S., Zamzmi, G., Goldgof, D., Kasturi, R., Ho, T., Sun, Y.: First investigation into the use of deep learning for continuous assessment of neonatal postoperative pain. In: IEEE International Conference on Automatic Face and Gesture Recognition, pp. 415–419 (2020)
  31. [30] Lu, G., Hao, Q., Kong, K., Yan, J., Li, H., Li, X.: Deep convolutional neu- ral networks with transfer learning for Neonatal pain expression recognition. In: International Conference on Natural Computation, Fuzzy Systems and Knowledge Discovery, pp. 251–256 (2018)
  32. [31] Zamzmi, G., Goldgof, D., Kasturi, R., Sun, Y.: Neonatal pain expression recognition using transfer learning. arXiv preprint arXiv:1807.01631 (2018)
  33. [32] Salekin, M.S., Zamzmi, G., Goldgof, D., Kasturi, R., Ho, T., Sun, Y.: Multi- channel neural network for assessing neonatal pain from videos. In: IEEE International Conference on Systems, Man and Cybernetics, pp. 1551–1556 (2019)
  34. [33] Zhu, H., Zhao, Y., Chen, X., Luo, F., Mei, L., Chen, S., Pan, Y.: Video-based Neonatal pain assessment in uncontrolled conditions. IEEE Journal of Biomedical and Health Informatics (2023) 20
  35. [34] Sun, Y., Kommers, D., Wang, W., Joshi, R., Shan, C., Tan, T., Aarts, R.M., Pul, C., Andriessen, P., With, P.H.: Automatic and continuous discomfort detection for premature infants in a nicu using video-based motion analysis. In: International Conference of the IEEE Engineering in Medicine and Biology Society, pp. 5995– 5999 (2019)
  36. [35] Ashwini, K., Vincent, P.D.R., Srinivasan, K., Chang, C.-Y.: Deep learning assisted neonatal cry classification via support vector machine models. Frontiers in Public Health 9 (2021)
  37. [36] Salekin, M.S., Zamzmi, G., Goldgof, D., Kasturi, R., Ho, T., Sun, Y.: Multi- modal spatio-temporal deep learning approach for Neonatal postoperative pain assessment. Computers in Biology and Medicine 129, 104150 (2021)
  38. [37] Raeside, L.: Physiological measures of assessing infant pain: a literature review. British Journal of Nursing 20, 1370–1376 (2011)
  39. [38] Lindh, V., Wiklund, U., H˚akansson, S.: Heel lancing in term new-born infants: an evaluation of pain by frequency domain analysis of heart rate variability. Pain 80, 143–148 (1999)
  40. [39] Faye, P.M., De Jonckheere, J., Logier, R., Kuissi, E., Jeanne, M., Rakza, T., Storme, L.: Newborn infant pain assessment using heart rate variability analysis. The Clinical Journal of Pain 26, 777–782 (2010)
  41. [40] Weissman, A., Zimmer, E.Z., Aranovitch, M., Blazer, S.: Heart rate dynamics during acute pain in newborns. Pfl¨ugers Archiv-European Journal of Physiology 464, 593–599 (2012)
  42. [41] Walter, S., Gruss, S., Ehleiter, H., Tan, J., Traue, H.C., Werner, P., Al-Hamadi, A., Crawcour, S., Andrade, A.O., Silva, G.M.: The BioVid heat pain database data for the advancement and systematic validation of an automated pain recog- nition system. In: IEEE International Conference on Cybernetics, pp. 128–131 (2013)
  43. [42] Lu, Z., Ozek, B., Kamarthi, S.: Transformer encoder with multiscale deep learn- ing for pain classification using physiological signals. Frontiers in Physiology 14, 1294577 (2023)
  44. [43] Pouromran, F., Radhakrishnan, S., Kamarthi, S.: Exploration of physiological sensors, features, and machine learning models for pain intensity estimation. Plos one 16(7), 0254108 (2021)
  45. [44] Gupta, A.K., Saikia, T., Gupta, P., Dhall, A.: PainXtract: A multimodal system for multiclass pain classification using physiological signals. In: Companion Pro- ceedings of the International Conference on Multimodal Interaction. Association for Computing Machinery, ??? (2025). (to appear) 21
  46. [45] Yang, R., Guan, Z., Yu, Z., Feng, X., Peng, J., Zhao, G.: Non-contact pain recognition from video sequences with remote physiological measurements predic- tion. In: International Joint Conference on Artificial Intelligence, pp. 1231–1237. International Joint Conferences on Artificial Intelligence Organization, ??? (2021)
  47. [46] Gupta, P., Bhowmick, B., Pal, A.: Accurate heart-rate estimation from face videos using quality-based fusion. In: IEEE International Conference on Image Processing, pp. 4132–4136 (2017)
  48. [47] Sahoo, N.N., Murugesan, B., Das, A., Karthik, S., Ram, K., Leonhardt, S., Joseph, J., Sivaprakasam, M.: Deep learning based non-contact physiological mon- itoring in Neonatal Intensive Care Unit. In: International Conference of the IEEE Engineering in Medicine & Biology Society, pp. 1327–1330 (2022)
  49. [48] Gupta, P., Bhowmik, B., Pal, A.: Robust adaptive heart-rate monitoring using face videos. In: IEEE Winter Conference on Applications of Computer Vision, pp. 530–538 (2018)
  50. [49] Wang, C.-Y., Bochkovskiy, A., Liao, H.-Y.M.: YOLOv7: Trainable bag-of-freebies sets new state-of-the-art for real-time object detectors. In: IEEE/CVF Conference on Computer Vision and Pattern Recognition, pp. 7464–7475 (2023)
  51. [50] Zhao, C., Han, W., Chen, Z., Li, Y., Feng, Y.: Remote estimation of heart rate based on multi-scale facial rois. In: Proceedings of the IEEE/CVF Conference on Computer Vision and Pattern Recognition Workshops, pp. 278–279 (2020)
  52. [51] Hutchon, D.J.: The normal range of heart rate at birth in a healthy term Neonate: a critical review of the evidence. Current Pediatric Research 20, 7–10 (2016)
  53. [52] Fleming, S., Thompson, M., Stevens, R., Heneghan, C., Pl¨uddemann, A., Maconochie, I., Tarassenko, L., Mant, D.: Normal ranges of heart rate and res- piratory rate in children from birth to 18 years of age: a systematic review of observational studies. The Lancet 377, 1011–1018 (2011)
  54. [53] Hospital, N.C.: Physical Exam of the Newborn — nationwidechil- drens.org. https://www.nationwidechildrens.org/conditions/health-library/ physical-exam-of-the-newborn#:∼:text=Normally%20120%20to%20160% 20beats,to%2060%20breaths%20per%20minute. [Accessed 10-02-2024]
  55. [54] Papadias, C.B.: A multi-user kurtosis algorithm for blind source separation. In: IEEE International Conference on Acoustics, Speech, and Signal Processing, vol. 5, pp. 3144–3147 (2000)
  56. [55] Liu, Y., Xu, C., Qi, L., Li, Y.: A robust non-contact heart rate estimation from facial video based on a non-parametric signal extraction model. Biomedical Signal Processing and Control 93, 106186 (2024) 22
  57. [56] Saeb, S., Lonini, L., Jayaraman, A., Mohr, D.C., Kording, K.P.: The need to approximate the use-case in clinical machine learning. Gigascience 6(5) (2017)
  58. [57] Wang, Q., Wang, M., Yang, Y., Zhang, X.: Multi-modal emotion recognition using EEG and speech signals. Computers in Biology and Medicine 149, 105907 (2022)
  59. [58] Kurpukdee, N., Kasuriya, S., Chunwijitra, V., Wutiwiwatchai, C., Lamsrichan, P.: A study of support vector machines for emotional speech recognition. In: Interna- tional Conference of Information and Communication Technology for Embedded Systems, pp. 1–6 (2017)
  60. [59] Shon, S., Ali, A., Glass, J.: Convolutional neural networks and language embeddings for end-to-end dialect recognition. In: The Speaker and Language Recognition Workshop, pp. 98–104 (2018)
  61. [60] Liu, Z., Hu, H., Lin, Y., Yao, Z., Xie, Z., Wei, Y., Ning, J., Cao, Y., Zhang, Z., Dong, L., et al.: Swin Transformer v2: Scaling up capacity and resolution. In: IEEE/CVF Conference on Computer Vision and Pattern Recognition, pp. 12009–12019 (2022)
  62. [61] Dosovitskiy, A., Beyer, L., Kolesnikov, A., Weissenborn, D., Zhai, X., Unterthiner, T., Dehghani, M., Minderer, M., Heigold, G., Gelly, S., Uszkoreit, J., Houlsby, N.: An image is worth 16x16 words: Transformers for image recognition at scale. In: International Conference on Learning Representations. OpenReview.net, ??? (2021)
  63. [62] Deng, J., Dong, W., Socher, R., Li, L.-J., Li, K., Fei-Fei, L.: Imagenet: A large- scale hierarchical image database. In: IEEE Conference on Computer Vision and Pattern Recognition, pp. 248–255 (2009)
  64. [63] Wolf, T., Debut, L., Sanh, V., Chaumond, J., Delangue, C., Moi, A., Cistac, P., Rault, T., Louf, R., Funtowicz, M., et al.: Transformers: State-of-the-art natural language processing. In: Conference on Empirical Methods in Natural Language Processing: System Demonstrations, pp. 38–45 (2020)
  65. [64] Yang, S., Luo, P., Loy, C.-C., Tang, X.: Wider Face: A face detection benchmark. In: IEEE Conference on Computer Vision and Pattern Recognition, pp. 5525–5533 (2016)
  66. [65] Grooby, E., Sitaula, C., Ahani, S., Holsti, L., Malhotra, A., Dumont, G.A., Marzbanrad, F.: Neonatal face and facial landmark detection from video record- ings. In: International Conference of the IEEE Engineering in Medicine & Biology Society, pp. 1–5 (2023)
  67. [66] Le, T.T., Fu, W., Moore, J.H.: Scaling tree-based automated machine learning to biomedical big data with a feature set selector. Bioinformatics 36, 250–256 (2020) 23
  68. [67] Olson, R.S., Bartley, N., Urbanowicz, R.J., Moore, J.H.: Evaluation of a tree- based pipeline optimization tool for automating data science. In: Genetic and Evolutionary Computation Conference, pp. 485–492 (2016)
  69. [68] Pedregosa, F., Varoquaux, G., Gramfort, A., Michel, V., Thirion, B., Grisel, O., Blondel, M., Prettenhofer, P., Weiss, R., Dubourg, V., Vanderplas, J., Passos, A., Cournapeau, D., Brucher, M., Perrot, M., Duchesnay, E.: Scikit-learn: Machine learning in Python. Journal of Machine Learning Research 12, 2825–2830 (2011)
  70. [69] Shchelkanova, E., Shchapova, L., Shchelkanov, A., Shibata, T.: Blue as an under- rated alternative to green: Photoplethysmographic heartbeat intervals estimation under two temperature conditions. Sensors 21, 4241 (2021)
  71. [70] Gajinov, Z., Matic, M., Prcic, S., Duran, V.: Optical properties of the human skin. Serbian Journal of Dermatology and Venereology 2, 131–136 (2013)
  72. [71] Rahma, A., Lane, M.E.: Skin barrier function in infants: update and outlook. Pharmaceutics 14, 433 (2022)
  73. [72] Ding, Y., Dai, Y., Cao, L., Tian, J., Lin, Z., Feng, L.: Detecting stress from videos via intra-subject and inter-subject learning. Health Information Science and Systems 14(1), 53 (2026)
  74. [73] Mej´ıa-Mej´ıa, E., Kyriacou, P.A.: Duration of photoplethysmographic signals for the extraction of pulse rate variability indices. Biomedical Signal Processing and Control 80, 104214 (2023)
  75. [74] Shaffer, F., Meehan, Z.M., Zerr, C.L.: A critical review of ultra-short-term heart rate variability norms research. Frontiers in Neuroscience 14, 594880 (2020)
  76. [75] Shaffer, F., Ginsberg, J.P.: An overview of heart rate variability metrics and norms. Frontiers in public health 5, 258 (2017)
  77. [76] Makowski, D., Pham, T., Lau, Z.J., Brammer, J.C., Lespinasse, F., Pham, H., Sch¨olzel, C., Chen, S.H.A.: NeuroKit2: A python toolbox for neurophysiological signal processing. Behavior Research Methods 53(4), 1689–1696 (2021)
  78. [77] Zhang, S., Li, C.: Research on feature fusion speech emotion recognition technol- ogy for smart teaching. Mobile Information Systems 2022 (2022)
  79. [78] Gupta, A.K., Dhamaniya, A., Gupta, P.: RADIANCE: Reliable and interpretable depression detection from speech using transformer. Computers in Biology and Medicine 183, 109325 (2024)
  80. [79] Venkataramanan, K., Rajamohan, H.R.: Emotion recognition from speech. arXiv preprint arXiv:1912.10458 (2019)
  81. [80] Russakovsky, O., Deng, J., Su, H., Krause, J., Satheesh, S., Ma, S., Huang, Z., 24
  82. Karpathy, A., Khosla, A., Bernstein, M., Berg, A.C., Fei-Fei, L.: ImageNet Large Scale Visual Recognition Challenge. International Journal of Computer Vision 115, 211–252 (2015)
  83. [81] Lu, G., Chen, H., Wei, J., Li, X., Zheng, X., Leng, H., Lou, Y., Yan, J.: Video-based neonatal pain expression recognition with cross-stream attention. Multimedia Tools and Applications 83(2), 4667–4690 (2024)
  84. [82] Ferreira, L.A., Carlini, L.P., Coutrin, G.d.A.S., Heiderich, T.M., Balda, R.d.C.X., Moraes Barros, M.C., Guinsburg, R., Thomaz, C.E.: Disclosing neonatal pain in real-time: AI-derived pain sign from continuous assessment of facial expressions. Computers in Biology and Medicine 189, 109908 (2025) 25