手动、操纵杆还是力反馈控制?机器人介入神经放射学手术导航策略的体外对比研究 Manual, Joystick, or Haptic Control? An In Vitro Comparison of Navigation Strategies for Robotic Interventional Neuroradiology Procedures 预印本

⚠️ 本文为 预印本(arXiv 公开版本),尚未经过正式同行评审。作者自发公开,结论未经期刊审稿验证,阅读时请知悉。
发布时间:2026-07-08
👁️ 预览文献
💡 AI 中文简介
本研究比较了机器人介入神经放射学手术中四种操控方式:带力反馈的器械模拟控制器、无力反馈的器械模拟控制器、操纵杆输入以及手动操作。研究者开发了定制血管内机器人、器械模拟控制器和带力传感的神经血管体模,并邀请10位介入神经放射科医生(4名新手、6名专家)进行模拟导航。结果显示手动操作最快(平均47.7秒),所有方式的血管壁力均低于0.70牛的穿刺阈值,因此均安全;操纵杆导致的脱垂事件显著多于手动操作;专家比新手表现更好。结论是器械模拟控制器在多数指标上优于操纵杆,力反馈有积极趋势但未达显著。
领域医疗机器人 / 介入神经放射学
适合谁读需要一定专业背景
核心贡献1. 开发了集成力传感的定制血管内机器人、器械模拟控制器和神经血管体模平台,用于体外对比评估;2. 系统比较了四种操控方式(手动、带/不带力反馈的器械模拟控制器、操纵杆)在导航时间、血管壁力、错误置管和脱垂事件等指标上的表现。
关键数据手动导航最快(平均47.7秒),带力反馈248.7秒,无力反馈314.7秒,操纵杆392.6秒(p<0.001);所有方式血管壁力均低于0.70牛穿刺阈值;操纵杆脱垂事件显著多于手动(1.56 vs 0.13,p=0.018);专家错误置管少于新手(0.25 vs 0.62,p=0.035),施加血管壁力更小(p<0.0005);用户认为带/不带力反馈同样直观,且比操纵杆更直观(p=0.033)。
推荐理由如果你关心手术机器人到底该用手动、操纵杆还是力反馈,这篇体外研究用硬数据告诉你:器械模拟控制器更安全高效,力反馈虽未显著但值得期待。
关键词["血管内机器人", "介入神经放射学", "力反馈", "血管体模", "力传感", "远程操作"]

原文摘要

查看英文原文摘要

Objective: To evaluate robotic controller interfaces for interventional neuroradiology procedures in-vitro incorporating a force-sensing platform to assess safety. Methods: A custom endovascular robot, device-mimicking controller, and sensorized neurovascular phantom were developed. Ten interventional neuroradiologists (4 novices, 6 experts) performed simulated navigations using four control modalities: device-mimicking controllers with and without haptic feedback, joystick-based input, and manual navigation. Navigation time, peak vessel-wall forces, incorrect catheterisations, and prolapse events were assessed, alongside user analyses. Results: Manual navigation was fastest (mean 47.7 s) compared to haptic-on (248.7 s), haptic-off (314.7 s), and joystick (392.6 s) modalities (p<0.001). Regardless of controller type, vessel-wall forces were below the 0.70 N puncture threshold; therefore all modalities were considered safe. Joystick produced significantly more prolapse events than manual control (1.56 vs 0.13; p=0.018). Operator experience was relevant to performance: experts made fewer incorrect catheterisations than novices (0.25 vs 0.62; p=0.035) and applied less vessel-wall force (p<0.0005); these effects were sustained across controllers but accentuated when haptics were on. Users perceived haptic on and haptic off as similarly intuitive, and more intuitive than joystick (p=0.033). Conclusion: Device-mimicking robotic controllers outperform joystick interfaces on most metrics; haptic feedback shows promising but non-significant performance benefits.