血管形态分类的混合框架:基于离散几何的迂曲度特征测量、基于信息增益的特征选择与随机森林分类 A Hybrid Framework for Blood Vessel Morphology Classification: Discrete Geometry-based Tortuosity Feature Measurement, Information Gain-based Feature Selection, and Random Forest Classification 预印本
原文摘要
查看英文原文摘要
Subjective visual grading of blood vessel tortuosity relies heavily on clinical experience, while traditional distance-based indices often fail to adequately characterize three-dimensional spatial deformation. Because abnormal internal carotid artery morphology may be clinically relevant to cerebrovascular assessment and stroke-risk evaluation, objective and reproducible quantification of vascular tortuosity is of considerable importance. To address this limitation, we propose a mathematical framework for the morphological classification of the internal carotid artery (ICA-C1) segment. The framework integrates discrete geometric feature measurement, Information Gain-based feature selection, and Random Forest classification. An initial set of 13 tortuosity features is extracted from the corresponding 379 clinical vascular centerlines using discrete geometric methods and subsequently reduced to a six-feature subset consisting of $\mathcal{TI}$, $\mathcal{AC}$, $\mathcal{TC}$, $\mathcal{AC}/\mathcal{AT}$, $\mathcal{AT}$, and $\mathcal{TT}$. The framework is evaluated in two classification tasks. For binary classification of non-severe and severe tortuosity, the RF model achieves a Macro-F1 score of 0.9206. For ternary morphological grading into straight, low-tortuosity, and high-tortuosity groups, it achieves a Macro-F1 score of 0.8626. The results indicate that elongation- and curvature-related features provide strong discriminatory information for basic screening, whereas torsion-related features contribute additional information for more detailed morphological classification. Based on the RF feature-importance values, we further define a Morphological Risk Index (MRI), which provides a direct numerical reference for vascular morphology and may facilitate more objective and consistent clinical assessment.
📚 参考文献 (50 条)
查看全部 50 条
- [1] M. Aghamohamadian-Sharbaf, H. R. Pourreza, and T. Banaee, “A novel curvature-based algorithm for automatic grading of retinal blood vessel tortuosity,” IEEE Journal of Biomedical and Health Informatics, vol. 20, no. 2, pp. 586–595, 2016.
- [2] J. Amann, A. Blasimme, E. Vayena, D. Frey, and V. I. Madai, “Explainability for artificial intelligence in healthcare: a multi- disciplinary perspective,” BMC Medical Informatics and Decision Making, vol. 20, no. 1, pp. 1–9, 2020.
- [3] Y. An, C. Shao, X. Wang, and Z. Li, “Geometric properties estima- tion from discrete curves using discrete derivatives,” Computers & Graphics, vol. 35, no. 4, pp. 916–930, 2011.
- [4] Y. An, L. Wang, R. Ma, and J. Wang, “Geometric properties esti- mation from line point clouds using gaussian-weighted discrete derivatives,” IEEE Transactions on Industrial Electronics, vol. 68, no. 1, pp. 703–714, 2020.
- [5] L. Antiga, M. Piccinelli, L. Botti, and D. A. Steinman, “An image- based modeling framework for patient-specific computational hemodynamics,” Medical & Biological Engineering & Computing, vol. 46, no. 11, pp. 1097–1112, 2008.
- [6] S. R. Aylward and E. Bullitt, “Initialization, noise, singularities, and scale in height ridge traversal for tubular object centerline extraction,” IEEE Transactions on Medical Imaging, vol. 21, no. 2, pp. 61–75, 2002.
- [7] R. A. Baz, C. Scheau, C. Niscoveanu et al., “Morphometry of the entire internal carotid artery on ct angiography,” Medicina, vol. 57, no. 8, p. 832, 2021.
- [8] C. Blankenburg, C. Daul, and J. Ohser, “Parameter free torsion estimation of curves in 3d images,” in 2016 IEEE International Conference on Image Processing, 2016, pp. 1081–1085.
- [9] H. Bogunovi´c, J. M. Pozo, M. C. Villa-Uriol et al., “Auto- mated landmarking and geometric characterization of the carotid siphon,” Medical Image Analysis, vol. 16, no. 4, pp. 889–903, 2012.
- [10] A. Bouthillier, H. R. van Loveren, and J. T. Keller, “Segments of the internal carotid artery: a new classification,” Neurosurgery, vol. 38, no. 3, pp. 425–433, 1996.
- [11] L. Breiman, “Random forests,” Machine Learning, vol. 45, no. 1, pp. 5–32, 2001.
- [12] A. B. Brummer, D. Hunt, and V. Savage, “Improving blood vessel tortuosity measurements via highly sampled numerical integration of the frenet-serret equations,” IEEE Transactions on Medical Imaging, vol. 40, no. 1, pp. 297–309, 2020.
- [13] E. Bullitt, G. Gerig, S. Pizer, W. Lin, and S. Aylward, “Measuring tortuosity of the intracerebral vasculature from mra images,” IEEE Transactions on Medical Imaging, vol. 22, pp. 1163–1171, 2003.
- [14] H. Chen, C. Gomez, C.-M. Huang, and M. Unberath, “Explainable medical imaging AI needs human-centered design: Guidelines and evidence from a systematic review,” npj Digital Medicine, vol. 5, p. 156, 2022.
- [15] D. Coeurjolly and S. Miguet, “Estimating curvature and torsion of 3d curves from digital images,” Pattern Recognition Letters, vol. 25, no. 10, pp. 1181–1192, 2004.
- [16] G. S. Collins, K. G. M. Moons, P. Dhiman et al., “TRIPOD+AI statement: Updated guidance for reporting clinical prediction models that use regression or machine learning methods,” The BMJ, vol. 385, p. e078378, 2024.
- [17] R. Couronn´e, P. Probst, and A. L. Boulesteix, “Random forest versus logistic regression: a large-scale benchmark experiment,” BMC Bioinformatics, vol. 19, no. 1, p. 270, 2018.
- [18] T. M. Cover and J. A. Thomas, Elements of information theory. John Wiley & Sons, 1991. [Online]. Available: https: //onlinelibrary.wiley.com/doi/book/10.1002/0471200611
- [19] M. Decroocq, C. Frindel, P. Roug´e, M. Ohta, and G. Lavou´e, “Modeling and hexahedral meshing of cerebral arterial networks from centerlines,” Medical Image Analysis, vol. 89, p. 102912, 2023.
- [20] A. F. Frangi, W. J. Niessen, K. L. Vincken, and M. A. Viergever, “Multiscale vessel enhancement filtering,” in Medical Image Com- puting and Computer-Assisted Intervention–MICCAI’98, 1998, pp. 130–137.
- [21] M. Ghassemi, L. Oakden-Rayner, and A. L. Beam, “The false hope of current approaches to explainable artificial intelligence in health care,” The Lancet Digital Health, vol. 3, no. 11, pp. e745– e750, 2021.
- [22] M. Goyal, B. K. Menon, W. H. van Zwam et al., “Endovascu- lar thrombectomy after large-vessel ischaemic stroke: a meta- analysis,” The Lancet, vol. 387, no. 10029, pp. 1723–1731, 2016.
- [23] E. Grisan, M. Foracchia, and A. Ruggeri, “A novel method for the automatic grading of retinal vessel tortuosity,” IEEE Transactions on Medical Imaging, vol. 27, no. 3, pp. 310–319, 2008.
- [24] G. Haixiang, L. Yijing, J. Shang, G. Mingyun, H. Yuanyue, and Z. Bing, “Learning from class-imbalanced data: Review of meth- ods and applications,” Expert Systems with Applications, vol. 73, pp. 220–239, 2017.
- [25] M. J. Johnson and G. Dougherty, “Robust measures of three- dimensional vascular tortuosity,” Medical Engineering & Physics, vol. 29, no. 6, pp. 677–690, 2007.
- [26] V. Kashyap, R. Gharleghi, D. D. Li, L. McGrath-Cadell, R. M. Graham, C. Ellis, M. Webster, and S. Beier, “Accuracy of vascular tortuosity measures using computational modelling,” Scientific Reports, vol. 12, no. 1, p. 865, 2022.
- [27] J. Koge, K. Tanaka, T. Yoshimoto, M. Shiozawa, Y. Kushi et al., “In- ternal carotid artery tortuosity: impact on mechanical thrombec- tomy,” Stroke, vol. 53, no. 8, pp. 2458–2467, 2022.
- [28] K. Lekadir et al., “FUTURE-AI: International consensus guideline for trustworthy and deployable artificial intelligence in health- care,” The BMJ, vol. 388, p. e081554, 2025.
- [29] D. Lesage, E. D. Angelini, I. Bloch, and G. Funka-Lea, “A review of 3d vessel lumen segmentation techniques: Models, features and extraction schemes,” Medical Image Analysis, vol. 13, no. 6, pp. 819– 845, 2009.
- [30] J. Li, K. Cheng, S. Wang, F. Morstatter, R. P. Trevino, J. Tang, and H. Liu, “Feature selection: A data perspective,” ACM Computing Surveys (CSUR), vol. 50, no. 6, pp. 1–45, 2017.
- [31] S. Lorthois, F. Lauwers, and F. Cassot, “Tortuosity and other vessel attributes for arterioles and venules of the human cerebral cortex,” Microvascular Research, vol. 91, pp. 99–109, 2014.
- [32] K. V. Mardia, “Estimation of torsion,” Journal of Applied Statistics, vol. 26, no. 3, pp. 373–381, 1999.
- [33] R. G. Nogueira, A. P. Jadhav, D. C. Haussen et al., “Thrombectomy 6 to 24 hours after stroke with a mismatch between deficit and infarct,” New England Journal of Medicine, vol. 378, no. 1, pp. 11–21, 2018.
- [34] J. Oh et al., “In vitro analysis of the efficacy of endovascular thrombectomy techniques according to the vascular tortuosity using 3d printed models,” American Journal of Neuroradiology, vol. 43, no. 10, pp. 1431–1437, 2022.
- [35] V. Pancaldi et al., “Blood flow in the tortuous internal carotid artery,” Journal of Biomechanics, vol. 45, no. 11, pp. 1885–1890, 2012.
- [36] M. Piccinelli, A. Veneziani, D. A. Steinman, A. Remuzzi, and L. Antiga, “A framework for geometric analysis of vascular structures: Application to cerebral aneurysms,” IEEE Transactions on Medical Imaging, vol. 28, no. 8, pp. 1141–1155, 2009.
- [37] F. Puel, “Explicit solutions of the three-dimensional inverse prob- lem of dynamics, using the frenet reference frame,” Celestial Mechanics and Dynamical Astronomy, vol. 53, pp. 207–218, 1992.
- [38] M. Roberts, D. Driggs, M. Thorpe et al., “Common pitfalls and recommendations for using machine learning to detect and prog- nosticate for COVID-19 using chest radiographs and CT scans,” Nature Machine Intelligence, vol. 3, pp. 199–217, 2021.
- [39] P. Schober, C. Boer, and L. A. Schwarte, “Correlation coefficients: appropriate use and interpretation,” Anesthesia & Analgesia, vol. 126, no. 5, pp. 1763–1768, 2018.
- [40] C. E. Shannon, “A mathematical theory of communication,” The Bell System Technical Journal, vol. 27, no. 3, pp. 379–423, 1948.
- [41] M. Sokolova and G. Lapalme, “A systematic analysis of perfor- mance measures for classification tasks,” Information Processing & Management, vol. 45, no. 4, pp. 427–437, 2009.
- [42] M. Tomczak and E. Tomczak, “The need to report effect size estimates revisited. an overview of some recommended measures of effect size,” Trends in Sport Sciences, vol. 21, no. 1, pp. 19–25, 2014.
- [43] S. Tonekaboni, S. Joshi, M. D. McCradden, and A. Goldenberg, “What clinicians want: contextualizing explainable machine learning for clinical end use,” in Proceedings of the 4th Machine Learning for Healthcare Conference, 2019, pp. 359–380. [Online]. Available: https://proceedings.mlr.press/v106/tonekaboni19a.html
- [44] A. Vabalas, E. Gowen, E. Poliakoff, and A. J. Casson, “Machine learning algorithm validation with a limited sample size,” PLOS ONE, vol. 14, no. 11, p. e0224365, 2019.
- [45] B. Vasey, M. Nagendran, B. Campbell et al., “Reporting guideline for the early-stage clinical evaluation of decision support systems driven by artificial intelligence: DECIDE-AI,” Nature Medicine, vol. 28, no. 5, pp. 924–933, 2022.
- [46] J. R. Vergara and P. A. Est´evez, “A review of feature selection methods based on mutual information,” Neural Computing and Applications, vol. 24, no. 1, pp. 175–186, 2014.
- [47] L. F. Voges, L. C. Jarren, S. Seifert, and S. Szymczak, “Exploitation of surrogate variables in random forests for unbiased analysis of mutual impact and importance of features,” Bioinformatics, vol. 39, no. 8, p. btad471, 2023.
- [48] J. Weibel and W. S. Fields, “Tortuosity, coiling, and kinking of the internal carotid artery,” Neurology, vol. 15, no. 1, p. 7, 1965.
- [49] D. N. Wolman, A. M. Moraff, and J. J. Heit, “Anatomy of the intracranial arteries: the internal carotid artery,” Neuroimaging Clinics, vol. 32, no. 3, pp. 603–615, 2022.
- [50] X. Zhang, M. F. Luo, K. Fang, J. Li, Y. Peng et al., “Application of 3d curvature and torsion in evaluating aortic tortuosity,” Commu- nications in Nonlinear Science and Numerical Simulation, vol. 95, p. 105619, 2021.