基于自动提示选择的Segment Anything Model 2在微重力燃烧图像中液滴火焰直径的数字测量 Digital measurement of droplet flame diameter in microgravity combustion images using Segment Anything Model 2 with automatic prompt selection 预印本

⚠️ 本文为 预印本(arXiv 公开版本),尚未经过正式同行评审。作者自发公开,结论未经期刊审稿验证,阅读时请知悉。
发布时间:2026-07-18
👁️ 预览文献
💡 AI 中文简介
本研究针对微重力液滴燃烧图像中火焰直径难以自动测量的问题,提出一种结合自动提示点生成与Segment Anything Model 2的AI测量流程,并利用RANSAC圆拟合排除碳烟尾迹干扰。在19,537张正庚烷、正癸烷和正辛烷液滴火焰图像上验证,与人工测量相比平均相对一致率达96.9%,平均绝对百分比误差为3.1%,效率提升约229倍,为燃烧诊断提供了可重复的全自动数字测量方案。
领域燃烧诊断与图像测量,细分方向为微重力液滴燃烧与AI图像分割
适合谁读需要一定专业背景,适合燃烧学、图像处理或计量学领域的研究生与科研人员
核心贡献1. 将自动提示点生成与SAM2结合,实现无需人工干预的火焰直径测量,并利用视频记忆机制保持漂移液滴的时间一致性;2. 采用RANSAC圆拟合将碳烟尾迹像素作为几何异常值剔除,提高了测量鲁棒性和计量学表征。
关键数据在19,537张火焰图像上验证,与人工参考测量相比平均相对一致率96.9%,平均绝对百分比误差3.1%,合成标准不确定度8.54%,效率较人工测量提升约229倍,且测量精度随液滴尺寸增大而提高。
推荐理由如果你关注AI如何落地到燃烧诊断或需要高吞吐、可重复的火焰直径测量,这篇工作用SAM2加自动提示和RANSAC给出了漂亮答案,效率提升229倍,值得一读。
关键词["微重力燃烧", "液滴火焰直径", "Segment Anything Model 2", "自动提示选择", "RANSAC圆拟合", "数字图像测量"]

原文摘要

查看英文原文摘要

Flame diameter is a key measurable parameter in microgravity droplet combustion, but its extraction from self-illuminated frames remains difficult because soot tails, blurred luminous boundaries, chamber reflections, and droplet drift introduce substantial measurement bias and operator dependence. This work presents an AI-enabled digital measurement workflow for automated flame diameter from combustion images. The workflow integrates automatic prompt-point generation into Segment Anything Model 2, employing Random Sample Consensus (RANSAC)-based circle fitting. The automatic prompt strategy removes subjective manual point selection, while the video memory mechanism maintains temporal consistency for drifting droplets, and the RANSAC fitting rejects soot-tail pixels as geometric outliers. The method is validated by 19,537 flame images of n-heptane, n-decane, and n-octane droplets with varying initial diameters. Compared with manual-reference measurements, the proposed workflow achieves a mean relative agreement of 96.9%, a mean absolute percentage error of 3.1%, and substantially outperforms conventional Hough circle detection, which performed worse under the same evaluation conditions. The results also show that the measurement accuracy improves with increasing droplet size. The proposed workflow has a combined standard uncertainty of 8.54% and achieves approximately a 229-fold improvement in efficiency over manual measurement. These results demonstrate that the proposed SAM2-based workflow provides a reproducible, fully automated, and metrologically characterized digital measurement system for extracting flame diameter from challenging combustion images. The approach supports high-throughput combustion diagnostics and illustrates that AI-based segmentation can be integrated into quantitative measurement workflows for digitalized image-based metrology.