准SVD:学习一种李约束矩阵分解用于实时成像 Quasi-SVD: Learning a Lie-constrained matrix factorisation for real-time imaging 预印本

⚠️ 本文为 预印本(arXiv 公开版本),尚未经过正式同行评审。作者自发公开,结论未经期刊审稿验证,阅读时请知悉。
发布时间:2026-07-28
⬇️ 5 次下载
👁️ 预览文献
💡 AI 中文简介
本研究提出准SVD,一种可在GPU上完全并行运行的矩阵分解方法,用于实时医学成像。传统SVD算法是串行的,难以满足临床实时处理需求。准SVD只对一个因子施加李群参数化保证严格正交,另一个因子用软约束恢复,从而避免迭代优化奇异向量。在超声定位显微和穆勒矩阵偏振成像两个任务上,重建保真度SSIM达0.89-0.94,速度比cuSOLVER和随机SVD快3-20倍,吞吐超过25帧/秒,足以支持实时图像引导工作流。
领域计算成像与医学图像处理
适合谁读需要一定专业背景(矩阵分析、GPU计算或医学成像)
核心贡献1. 提出非对称李约束矩阵分解框架,仅对一个因子强制正交,避免迭代奇异向量优化,实现全并行GPU计算。2. 在两种互补医学成像任务中验证了框架的鲁棒迁移能力和实时吞吐性能。
关键数据重建保真度SSIM=0.89-0.94;相比cuSOLVER和随机SVD加速3-20倍;吞吐量超过25 FPS;在超声定位显微和穆勒矩阵偏振成像任务中均有效。
推荐理由如果你关心医学成像的实时处理,这篇论文用巧妙的数学设计把SVD速度提升了一个数量级,值得一读。
关键词["矩阵分解", "奇异值分解", "实时成像", "GPU并行计算", "医学图像处理", "李群约束"]

原文摘要

查看英文原文摘要

Singular Value Decomposition (SVD) underlies matrix factorisation tasks across computational imaging, with medical applications increasingly demanding real-time processing. Yet SVD algorithms are inherently sequential, constraining real-time GPU throughput and limit online deployment in clinical pipelines. This study introduces Quasi-SVD, a differentiable, fully parallelized matrix factorization framework for GPUs. Rather than enforcing orthogonality on both factors, it guarantees exact orthogonality for a single Lie-parameterized factor while recovering the remaining components through soft constraints, enabling efficient parallel decomposition without iterative singular-vector optimization. This asymmetric design, provably sufficient for valid factorisation, achieves reconstruction fidelity of SSIM = 0.89-0.94 and accelerates computation by 3-20x relative to cuSOLVER and randomised SVD, enabling throughput above 25 FPS. Performance is evaluated on two medical imaging tasks spanning complementary computational regimes: (1) spatio-temporal background subtraction for ultrasound localisation microscopy, requiring high-dimensional matrix separation, and (2) Mueller matrix polarimetry for neurosurgical tissue characterisation, requiring massive batch processing of small matrices. Across both regimes and multiple imaging instruments, the proposed framework demonstrates robust domain transfer and throughput exceeding 25 FPS at clinical matrix scales, a rate sufficient for live image-guided workflows that classical solvers cannot currently support in these settings. By prioritising downstream reconstruction fidelity over exact spectral recovery, Quasi-SVD makes structured matrix factorisation practical for real-time imaging.