用于非侵入式压力监测的低功耗可穿戴呼吸传感器 A Low-Power Wearable Respiratory Sensor for Non-Invasive Stress Monitoring 预印本

⚠️ 本文为 预印本(arXiv 公开版本),尚未经过正式同行评审。作者自发公开,结论未经期刊审稿验证,阅读时请知悉。
发布时间:2026-08-06
⬇️ 3 次下载
👁️ 预览文献
💡 AI 中文简介
本研究针对日常环境下呼吸监测难的问题,设计了一种基于力敏电阻(FSR)的腹部束带式可穿戴呼吸传感系统,配合自研低功耗蓝牙采集板,无需模拟放大即可捕捉腹部微小形变。研究在多种呼吸模式和体位下验证了信号质量,并设计了五阶段压力诱导实验,采集12名参与者的呼吸数据,用可解释的时域特征和标准分类器区分放松与压力状态,最佳模型测试准确率达88.0%,表明该平台有望用于情感计算等场景。
领域可穿戴生理传感与情感计算
适合谁读需要一定专业背景(生物医学工程、可穿戴设备、信号处理)
核心贡献1. 提出一种无需模拟放大、结构简单的FSR腹部束带呼吸传感系统,结合自研低功耗BLE采集板,可在日常场景实时监测呼吸;2. 设计五阶段压力诱导协议,验证了呼吸时域特征可有效区分压力与放松状态(最佳准确率88.0%)。
关键数据最佳分类模型测试准确率88.0%;12名参与者;五阶段压力诱导协议;无需模拟放大。
推荐理由如果你对用可穿戴设备监测压力和呼吸感兴趣,这篇工作用简单的FSR方案就做到了88%的识别准确率,硬件和算法都很轻量,值得一读。
关键词["可穿戴呼吸传感", "力敏电阻", "压力监测", "情感计算", "低功耗蓝牙"]

原文摘要

查看英文原文摘要

Respiration provides a continuously available window into physiological state and behavior. However, monitoring it outside controlled settings remains challenging because a wearable system must capture small body deformations while remaining comfortable, low power, and robust to changes in posture and motion. We present a compact non-invasive respiratory sensing system based on a force-sensitive resistor (FSR) embedded in an abdominal belt and integrated with a custom Bluetooth Low Energy acquisition board. The system combines a simple piezoresistive readout with a mechanical holder designed to transfer abdominal expansion to the sensor without analog amplification. We evaluate the complete sensing pipeline across multiple breathing patterns and body positions. In stationary settings, the recorded signals exhibit consistent amplitude changes and recurring peak-to-peak timing across breathing maneuvers; under light movement, these variations remain visible despite motion-induced baseline shifts. We further design a five-phase stress-induction protocol and collect respiratory recordings from 12 participants. Using interpretable time-domain features and standard classifiers, we examine whether the acquired signals distinguish relaxation from stress-induction phases. In this preliminary experiment, the best-performing model achieves 88.0% test accuracy, indicating that the extracted respiratory features distinguish stress-induced phases from relaxation phases in this dataset. Overall, our results show that the proposed platform enables real-time respiratory monitoring across diverse daily-life scenarios and captures respiratory changes that distinguish stress-induction from relaxation phases, supporting its potential for affective-computing applications.