ORION-CMR:基于集成基础模型的扫描仪端到端心脏磁共振分析与解读报告 ORION-CMR: On-scanner Reporting with Integrated Foundation Model for End-to-End Cardiac MRI Analysis and Interpretation 预印本

⚠️ 本文为 预印本(arXiv 公开版本),尚未经过正式同行评审。作者自发公开,结论未经期刊审稿验证,阅读时请知悉。
发布时间:2026-09-20
⬇️ 6 次下载
👁️ 预览文献
💡 AI 中文简介
心脏磁共振(CMR)检查流程复杂,限制了其临床应用。本研究提出ORION-CMR,一个在扫描仪上直接运行的端到端CMR基础模型,预训练了来自9258项研究的1289万余张图像。它能在约90秒内完成序列分类、心室功能评估、延迟强化检测、疾病分类及本地大语言模型报告生成。在68例多厂商队列中,正常与异常分类AUC达0.96,多疾病分类AUC为0.88,报告与专家解读一致率81.4%,性能超越现有监督模型和CMR-FM。
领域医学影像人工智能、心脏磁共振分析
适合谁读需要一定专业背景(医学影像AI或心血管领域研究者)
核心贡献1. 首个经临床评估的扫描仪原生端到端CMR基础模型,实现实时分析;2. 集成多任务与本地大语言模型,自动生成结构化报告。
关键数据预训练数据:12,896,733张CMR图像,来自9,258项研究;处理时间约90秒;正常vs异常分类AUC 0.96,多疾病分类AUC 0.88;报告与专家一致率81.4%;在LGE分类和瘢痕分割上达到最先进性能。
推荐理由想了解AI如何让心脏磁共振检查变得又快又准,还能自动写报告?这篇工作给出了临床验证的答案。
关键词["心脏磁共振", "基础模型", "端到端分析", "自动报告生成", "延迟钆增强", "临床验证"]

原文摘要

查看英文原文摘要

Cardiovascular magnetic resonance (CMR) provides comprehensive cardiac assessment but remains underutilized because of the complexity of acquisition, post-processing, and interpretation. Existing artificial intelligence (AI) methods address isolated tasks, limiting clinical integration. We present ORION-CMR (On-scanner Reporting with Integrated fOunda-tioN Model), the first clinically evaluated scanner-native end-to-end CMR foundation model. Pretrained on 12,896,733 CMR images from 9,258 studies, ORION-CMR performs sequence classification, ventricular function assessment, late gadolinium enhancement (LGE) detection, binary and multiclass disease classification, and local large language model-based report generation in approximately 90 seconds. The framework. was evaluated on public benchmarks and clinically validated in a multi-vendor cohort of 68 subjects with normal examinations, congenital heart disease, dilated cardiomyopathy, and myocardial infarction. ORION-CMR outperformed supervised baselines and the previously published CMR foundation model (CMR-FM), achieving state-of-the-art performance for LGE classification and scar segmentation. Clinical evaluation achieved an AUC of 0.96 for normal-versus abnormal classification and 0.88 for multiclass disease classification, while generated reports demonstrated 81.4% agreement with expert interpretation. These results demonstrate the feasibility of real-time scanner-native AI-assisted CMR analysis and automated report generation.