基于多示例学习的胎儿超声全检查先天性心脏病筛查 Towards Whole-Study Screening for Congenital Heart Disease in Fetal Ultrasound Using Multiple Instance Learning 预印本

⚠️ 本文为 预印本(arXiv 公开版本),尚未经过正式同行评审。作者自发公开,结论未经期刊审稿验证,阅读时请知悉。
发布时间:2026-09-25
⬇️ 1 次下载
👁️ 预览文献
💡 AI 中文简介
先天性心脏病是最常见的出生缺陷,但产前超声常漏诊。现有AI方法需要先由医生或模型挑出关键帧,本研究去掉这一前提,直接对整份超声检查做筛查。方法分两步:先在无标注胎儿超声上用自监督掩码自编码器预训练,再用疾病鲁棒模块找出心脏帧,并用基于Transformer的多示例学习模型仅凭检查级标签给出病例诊断,同时返回高分帧供医生复核。内部测试AUC达0.985,外部数据经无标签CORAL适配后AUC从0.513升至0.944,显示全检查筛查可行且可部署。
领域医学图像分析/胎儿超声AI辅助诊断
适合谁读需要一定专业背景(医学AI、超声影像或机器学习方向的研究者与工程师)
核心贡献1. 提出全检查级多示例学习框架,无需预先挑出关键帧,直接利用检查级标签进行先心病筛查;2. 设计疾病鲁棒的心脏帧识别模块与Transformer聚合,并返回高分帧供临床复核,同时用分层头区分危重与非危重先心病。
关键数据内部测试集AUC 0.985、特异性0.990,优于NATMED集成(AUC 0.861、特异性0.600)和FetalCLIP(AUC 0.867、特异性0.710);外部独立队列初始接近随机,经无标签CORAL适配后AUC从0.513提升至0.944,而全检查与视图依赖基线无法恢复。
推荐理由如果你关心AI如何从整份胎儿超声检查中自动筛查先心病,并解决跨中心部署难题,这篇工作用多示例学习和域适应给出了高精度且可落地的方案,值得一读。
关键词["先天性心脏病", "胎儿超声", "多示例学习", "自监督预训练", "产前筛查", "域适应"]

原文摘要

查看英文原文摘要

Congenital heart disease (CHD) is the most common birth defect, yet a large fraction of cases remain undetected on prenatal ultrasound, in part because current artificial-intelligence methods assume that the key diagnostic frames have already been isolated from a study, by a clinician or by a view classifier. We remove that assumption and address CHD screening directly at the level of the whole ultrasound study. We propose a two-stage framework that first learns transferable frame representations by self-supervised masked-autoencoder pre-training on unlabeled fetal ultrasound, then identifies cardiac frames with a disease-robust module and aggregates them with a transformer-based multiple instance learning (MIL) model that produces a case-level diagnosis from study-level labels alone. The model further returns its highest-scoring frames for clinician review, and a hierarchical head separates critical from non-critical CHD. On the internal test set of our multi-source development cohort (FUSE), the proposed cardiac-gated MIL model reaches an area under the curve (AUC) of 0.985 with a specificity of 0.990, outperforming the reproduced NATMED ensemble (AUC 0.861, specificity 0.600) and the FetalCLIP foundation model (AUC 0.867, specificity 0.710). On an independent external cohort, all models initially perform near chance, but label-free CORAL adaptation raises the proposed model from an AUC of 0.513 to 0.944, whereas whole-study and view-dependent baselines do not recover. These results indicate that whole-study MIL with disease-robust cardiac-frame identification is an accurate and deployable route to prenatal CHD screening.