基于图像的乳腺植入物检测用于乳腺X线摄影数据集策展与近实时部署:基础模型与任务专用卷积模型的比较 Image-Based Breast Implant Detection for Mammography Dataset Curation and Near-Real-Time Deployment: Comparing Foundation Models and Task-Specific Convolutional Models 预印本

⚠️ 本文为 预印本(arXiv 公开版本),尚未经过正式同行评审。作者自发公开,结论未经期刊审稿验证,阅读时请知悉。
发布时间:2026-10-01
⬇️ 7 次下载
👁️ 预览文献
💡 AI 中文简介
本研究比较了基础模型(RAD-DINO、MammoCLIP)和从零训练的任务专用卷积网络(ResNet18、轻量级ResNetLite)在乳腺X线摄影中检测乳腺植入物的性能与部署可行性。使用5000张单侧筛查图像训练,1000张测试。结果显示所有模型均表现优异,MammoCLIP的AUROC最高(0.999),RAD-DINO灵敏度最高(0.980),而ResNetLite仅用1.4%的参数就达到与ResNet18相当的精度,且推理最快。结论是模型选择应基于部署场景:GPU医院可选MammoCLIP,资源受限环境可选轻量级CNN。
领域医学图像分析/乳腺影像
适合谁读需要一定专业背景(医学影像分析或深度学习基础)
核心贡献1. 系统比较了基础模型与任务专用CNN在乳腺植入物检测中的性能与效率权衡;2. 提出轻量级ResNetLite,以极低参数量实现与ResNet18相当的精度,适合边缘部署。
关键数据MammoCLIP AUROC 0.999,训练时间493秒;RAD-DINO灵敏度0.980,准确率0.989;ResNetLite AUROC 0.993,准确率0.976,参数量仅为ResNet18的1.4%,推理最快。
推荐理由如果你关心医学影像模型的实际部署,这篇论文用硬数据告诉你:大模型不一定最优,轻量级网络也能又快又准。
关键词["乳腺植入物检测", "乳腺X线摄影", "基础模型", "卷积神经网络", "模型部署", "医学图像分析"]

原文摘要

查看英文原文摘要

Purpose: To evaluate the performance-feasibility tradeoffs of foundation models (FMs) and task-specific convolutional neural networks (CNNs) trained from scratch for breast implant classification in 2D mammography, with emphasis on suitability for near real-time clinical deployment. Methods: We evaluated four models: two FMs (RAD-DINO and MammoCLIP) and two CNNs trained from scratch for implant prediction (ResNet18 and our lightweight ResNetLite). Using the Emory Breast Imaging Dataset, 5,000 unilateral screening mammograms were used for training/validation and 1,000 manually reviewed unilateral images were held out for testing. For the FMs, global image embeddings from the pretrained encoder were classified using a support vector machine (SVM). The CNNs were trained end-to-end on 2D mammograms, with ResNetLite optimized via grid search over depth and width to balance accuracy and efficiency. Performance was evaluated using AUROC, sensitivity, specificity, accuracy, embedding visualization, and inference-latency. Results: All models demonstrated strong performance on held-out test data (n = 1,000). MammoCLIP achieved the highest AUROC (0.999) with the quickest training time of 493 seconds. RAD-DINO achieved the highest sensitivity (0.980; accuracy 0.989) but had the slowest inference and training times. ResNet18 and MammoCLIP achieved comparable accuracy (0.985). ResNetLite showed no statistically significant difference from ResNet18 (AUROC 0.993; accuracy 0.976) despite using only 1.4% of ResNet18's parameters, and had the fastest inference time. Conclusion: FMs and task-specific CNN models reliably detect breast implants on 2D mammography. Model selection is best guided by deployment context: MammoCLIP for GPU-equipped hospital settings requiring scalable integration, and lightweight CNNs such as ResNetLite for resource-constrained or edge deployments.