基于Dempster-Shafer融合的证据多模态Transformer情感识别 Evidential Multimodal Transformers with Dempster-Shafer Fusion for Emotion Recognition 预印本

⚠️ 本文为 预印本(arXiv 公开版本),尚未经过正式同行评审。作者自发公开,结论未经期刊审稿验证,阅读时请知悉。
发布时间:2026-10-09
👁️ 预览文献
💡 AI 中文简介
针对多模态情感识别中softmax方法在传感器数据损坏或矛盾时仍给出高置信度的问题,提出EMT-DS模型。它将预测建模为主观意见(Dirichlet分布),分离认知不确定性与偶然不确定性,并用Dempster组合规则融合各模态信念质量,显式量化冲突。在四个基准上,IEMOCAP准确率达84.3%(基线81.7%),DEAP为82.4%(基线78.1%),KEMDy20达96.8%,CMU-MOSEI提升2.4点;校准误差从0.153降至0.042,强噪声下保持71.2%准确率,且冲突指标可辅助选择性预测。
领域多模态情感计算/不确定性机器学习
适合谁读需要一定专业背景(了解Transformer、证据理论或情感识别基础)
核心贡献1. 提出EMT-DS框架,用主观意见和Dempster组合规则显式建模并融合多模态证据,将矛盾量化为冲突系数,避免强制共识;2. 融合步骤复杂度O(MK²),低于跨模态注意力的O(M²d²),且冲突指标可有效标记错误样本。
关键数据IEMOCAP准确率84.3%(基线81.7%,p<0.01);DEAP留一被试82.4%(基线78.1%);KEMDy20 96.8%;CMU-MOSEI提升2.4点;ECE从0.153降至0.042;音频强高斯噪声(σ=1.0)下保持71.2%(注意力基线45.3%);审查20%样本可捕获80%误分类。
推荐理由如果你关心模型在传感器出错或模态矛盾时还能不能靠谱,这篇用证据理论把“不确定”算得明明白白,准确率和校准双赢,值得一读。
关键词["多模态情感识别", "证据深度学习", "Dempster-Shafer理论", "不确定性量化", "Transformer", "冲突融合"]

原文摘要

查看英文原文摘要

Softmax-based multimodal emotion recognition methods often assign high confidence even when sensor data are corrupted or contradictory, for example when facial expressions suggest positive valence while vocal prosody indicates negative arousal. We present an Evidential Multimodal Transformer with Dempster-Shafer Fusion (EMT-DS) that addresses this problem through formal uncertainty quantification. EMT-DS models predictions as Subjective Opinions (Dirichlet distributions), separating epistemic uncertainty (lack of evidence) from aleatoric uncertainty (sensor noise). Modality-specific transformer encoders produce belief mass distributions that are fused with Dempster's Rule of Combination, which normalizes the joint belief mass by a conflict coefficient 1/(1-c), so that contradictory evidence is explicitly quantified as conflict and the fused prediction becomes diffuse rather than being forced into an unjustified consensus. Under subject-independent and speaker-independent evaluation on four benchmarks, EMT-DS achieves 84.3% accuracy on IEMOCAP versus 81.7% for the best baseline (p < 0.01), 82.4% on DEAP under leave-one-subject-out evaluation versus 78.1%, and 96.8% on the highly imbalanced KEMDy20, and it improves accuracy on CMU-MOSEI by 2.4 points over the strongest evidential baseline. In controlled ablation, it reduces Expected Calibration Error from 0.153 (softmax transformer) to 0.042. It maintains 71.2% accuracy under severe Gaussian noise on audio features (sigma = 1.0), where attention baselines drop to 45.3%, and degrades gracefully when entire modalities are absent. The fusion step has O(MK^2) complexity, compared with O(M^2 d^2) for cross-modal attention. The learned conflict metric also flags likely errors: reviewing 20% of samples captures 80% of misclassifications, which supports selective prediction in clinical and safety-critical systems.