H&E染色全切片图像中伪影分割方法的基准测试与改进 Benchmarking and Improvement of Artifact Segmentation Methods in H&E-Stained Whole Slide Imaging 预印本

⚠️ 本文为 预印本(arXiv 公开版本),尚未经过正式同行评审。作者自发公开,结论未经期刊审稿验证,阅读时请知悉。
发布时间:2026-10-16
⬇️ 1 次下载
👁️ 预览文献
💡 AI 中文简介
本研究系统评测了六种公开的H&E染色全切片图像伪影分割算法,使用两个公开数据集和一个新发布的多中心多器官数据集,从分割质量(Dice指数、召回率、误检率)和处理时间两方面进行比较。结果显示HistoKit(改进的GrandQC)性能最佳,HistoQC最差,暗斑和失焦区域较难分割。作者还提出一种简单后处理步骤进一步提升了HistoKit的性能,为伪影分割方法的评估与开发建立了参考基准。
领域计算病理学/医学图像分析
适合谁读需要一定专业背景(医学图像处理或病理学知识)
核心贡献1. 首次对多种公开伪影分割方法进行系统性多数据集基准测试,涵盖多中心多器官数据;2. 提出简单后处理步骤,显著提升最佳方法HistoKit的分割性能。
关键数据HistoKit(改进的GrandQC)性能最佳,HistoQC最差;暗斑和失焦区域分割难度较高;后处理步骤进一步提升了HistoKit的分割性能。
推荐理由如果你在开发病理图像质量控制工具,这篇基准测试能帮你快速选型并了解各方法优劣,还附带一个简单有效的性能提升技巧。
关键词["全切片图像", "伪影分割", "H&E染色", "计算病理学", "基准测试", "质量控制"]

原文摘要

查看英文原文摘要

Technical artifacts introduced during tissue preparation or slide scanning remain a major obstacle to developing robust computational pathology algorithms for hematoxylin and eosin (HE)-stained whole-slide images (WSIs). Despite the growing number of quality-control tools, their real-world utility remains hard to assess because of the limited number of publicly available implementations and the lack of systematic, multi-dataset comparisons. This paper presents a benchmark of artifact segmentation methods for HE-stained WSIs. After a literature review, six publicly available algorithms were selected and compared in terms of their ability to segment artifact-free tissue and selected artifact classes. Two publicly available datasets and a newly introduced dataset released to support further research were used for evaluation. Tissue samples from multiple medical centers and different organs are included, enabling evaluation across heterogeneous data sources. Segmentation performance was assessed using Dice Index, pixel-level recall, and false discovery rate for artifact-free tissue segmentation. For algorithms supporting multiclass artifact segmentation, class-wise Dice Index and inter-class misclassification were evaluated. In addition to segmentation quality, processing time was assessed. Statistical analysis revealed significant differences in segmentation performance between methods. HistoKit, which incorporates a modified version of the GrandQC, was identified as the best-performing algorithm, while HistoQC was the worst. In terms of artifact types, dark spots and out of focus regions were harder to segment than others. Finally, a simple post-processing step was introduced for HistoKit, which further improved segmentation performance. The benchmark establishes a reference for evaluating and developing artifact segmentation methods for HE-stained WSIs.