肌电信号令牌化以极低比特率保留运动信息 EMG Tokenization Preserves Movement Information at a Fraction of the Bitrate 预印本

⚠️ 本文为 预印本(arXiv 公开版本),尚未经过正式同行评审。作者自发公开,结论未经期刊审稿验证,阅读时请知悉。
发布时间:2026-10-23
⬇️ 1 次下载
👁️ 预览文献
💡 AI 中文简介
无线肌电接口需要在电极覆盖和传输带宽之间权衡。本研究提出用紧凑的肌电令牌替代原始信号,在320通道、9名参与者的实验中,令牌化使三维手部姿态解码误差仅增加0.01至0.45毫米,满足1毫米非劣效标准,同时数据量比原始肌电减少41倍。在176人的公开数据集上同样验证有效,且可在微控制器上20毫秒内完成63通道令牌生成。
领域生物医学信号处理 / 肌电接口与运动解码
适合谁读需要一定专业背景(肌电信号处理、可穿戴传感或神经接口方向)
核心贡献1. 证明无姿态标签训练的因果令牌化器能在数据量缩减约40倍的情况下保持三维手部姿态解码精度;2. 提出令牌作为可穿戴传感与解码器之间的固定紧凑接口,允许解码器更新而无需改动前端编码与传输表示。
关键数据320通道肌电、9名参与者;SPAR令牌化解码误差平均增加0.01毫米(95%CI -0.12~0.14),学习表示增加0.45毫米(0.10~0.82),均满足1毫米非劣效标准;存储令牌比原始肌电减少41倍、比连续SPAR特征减少36倍;emg2pose基准176名参与者上误差差异低于0.05毫米;Cortex-M55微控制器上63通道令牌生成耗时20毫秒以内。
推荐理由如果你关心可穿戴肌电设备如何少传数据又不丢动作信息,这篇用硬数据给出了近乎无损的压缩方案,值得一读。
关键词["肌电信号", "令牌化", "手部姿态解码", "无线可穿戴接口", "数据压缩", "低比特率传输"]

原文摘要

查看英文原文摘要

Wireless electromyography (EMG) interfaces must balance electrode coverage against transmission bandwidth. Here, we show that compact EMG tokens substantially reduce payload while retaining information for three-dimensional hand-pose decoding. We evaluate two causal tokenizers fitted without pose labels: an encoder pretrained to reconstruct EMG spectra and one based on SPAR, an engineered spectral-spatial representation of neighbouring electrodes. In personalized, within-session experiments with 320-channel EMG from nine participants, we compare tokenized and continuous features using matched decoder architectures and training procedures. Averaged across decoders, tokenization changed mean error by +0.01 mm for SPAR (95% confidence interval: -0.12 to 0.14) and +0.45 mm for the learned representation (0.10 to 0.82). Both increases met a 1 mm non-inferiority criterion. Stored token arrays reduced payloads 41-fold relative to raw EMG and 36-fold relative to continuous SPAR features. On sampled windows of the public emg2pose benchmark's test partition, absolute differences in mean error between learned tokens and continuous features were below 0.05 mm across 176 participants and in the subset of 20 participants unseen during training. Electrode coverage, calibration, and unseen recordings affected SPAR decoding more than quantization did. In a computational benchmark, optimized SPAR generated tokens for 63 channels within 20 ms on a Cortex-M55 microcontroller. These findings support tokenization as a compact interface between wearable sensing and movement decoding, allowing decoders to be updated while the wearable encoder and transmitted representation remain fixed.