面向ICU出院风险评估的操作感知多模态临床决策支持系统 Operation-aware Multimodal Clinical Decision Support System for ICU Discharge Risk Assessment 预印本

⚠️ 本文为 预印本(arXiv 公开版本),尚未经过正式同行评审。作者自发公开,结论未经期刊审稿验证,阅读时请知悉。
发布时间:2026-11-09
👁️ 预览文献
💡 AI 中文简介
本研究针对ICU患者30天非计划再入院风险预测问题,指出现有模型忽略医院运营背景和资源容量。为此开发了操作感知的多模态临床决策支持系统,融合多智能体协作提取、自进化RAG、科室工作负荷指标、生命体征和稀疏医疗编码,并处理类别不平衡和警报疲劳。在MIMIC-III的2万次ICU住院数据上实验表明,端到端多模态微调架构表现最佳,AUROC达0.8288,PR-AUC为0.4373,F1为0.4757,运营指标提供独立风险信号,为高实用性临床决策支持工具奠定工程基础。
领域医疗人工智能/临床决策支持
适合谁读需要一定专业背景(医学信息学、机器学习基础)
核心贡献1. 提出操作感知的多模态CDSS,首次将医院运营指标(工作负荷、入院流量)与患者生理数据结合用于ICU出院风险评估;2. 设计端到端多模态微调架构,通过逐层参数冻结和差异化学习率解决文本负迁移问题,显著提升预测性能。
关键数据在MIMIC-III的20,000次ICU住院数据上,端到端多模态微调架构达到AUROC 0.8288±0.0110、PR-AUC 0.4373±0.0310、F1-Score 0.4757±0.0196;仅生命体征PR-AUC仅0.1387±0.0086;直接拼接原始文本嵌入导致XGBoost和LightGBM的PR-AUC降至0.3893和0.4030。
推荐理由如果你关注医疗AI落地,这篇工作把‘床位周转压力’这种现实因素纳入模型,性能提升明显,值得一读!
关键词["ICU再入院风险", "临床决策支持系统", "多模态学习", "操作感知", "检索增强生成", "类别不平衡"]

原文摘要

查看英文原文摘要

Unplanned 30-day intensive care unit (ICU) readmission is a critical benchmark for evaluating healthcare quality. Most predictive models assume readmission risk depends solely on a patient's individual pathophysiological state, ignoring hospital operational context and resource capacity. In practice, discharge decisions are dynamic trade-offs between patient stability and bed turnover pressures. To address this gap, we develop an Operation-aware Multimodal Clinical Decision Support System (CDSS) for ICU discharge risk assessment. The system combines multi-agent collaborative extraction with self-evolving retrieval-augmented generation (RAG) to eliminate template noise from progress notes, while constructing departmental workload indicators alongside admission flow features, continuous vital signs, and sparse medical codes (ICD/DRG). Addressing severe class imbalance (about 10.5% readmissions) and alarm fatigue, we implement data normalization, class reweighting, and decision-threshold calibration. In 20 independent runs across 20,000 ICU stays from MIMIC-III, empirical findings demonstrate that: vital signs alone have limited predictive capacity under real-world class imbalance (PR-AUC of 0.1387 +/- 0.0086); directly concatenating raw text embeddings degrades decision tree performance (XGBoost and LightGBM PR-AUC drop to 0.3893 and 0.4030); whereas an end-to-end multimodal fine-tuning architecture (Transformer E2E FineTune) utilizing layer-wise parameter freezing and differential learning rates reverses text negative transfer, achieving the highest AUROC of 0.8288 +/- 0.0110, PR-AUC of 0.4373 +/- 0.0310, and F1-Score of 0.4757 +/- 0.0196. Operational indicators supply independent risk signals, laying an engineering foundation for high-utility clinical decision support tools.